1. Introduce
XJP600 polarizing microscope is utilized polarizing light to observe and research the matter which have double refraction features, enable to observe in single polarizing, orthogonal, iconoscope. It can be applied in geology, chemicals, physic and leech Dom fields, widely used to observe the crystal of liquid macromolecule polymer, biomedical polymer and liquid crystal. It is the ideal instrument for scientific research and universities teaching demo.
Features
▲Adopt infinity optical system.
▲Infinity with strain-free plan achromatic objectives, the field of view is widely and clear.
▲Wide-field plan eyepieces: field number Ф22mm.
▲Coaxial coarse/fine focus system, with tensional adjustable and up stop, minimum division of fine focusing: 2μm.
▲Take-down style polarizer, 360°rotatable, have 0,90,180,270 four scale, located down the aperture diaphragm
▲Impellent style analyzer, 360°rotatable, push in / out from optical path conveniently
▲Rotatable stage, 360° graduated in 1° increments, minimum retardation resolution 6' center adjustable and with tightener.
▲Wide voltage range power supply (85-265V 50/60Hz), 6V30W halogen lamp, brightness adjustable.
2. Structure
3. Image
Specification | XJP600 | |
Optical System | Infinite Plan Optical System F=200mm | ● |
Eyepiece tube | Trinocular is inclined 30˚ and enable to shoot in 100% light flux. | ● |
Eyepiece | Wide field WF10X=22mm | ● |
Dividing eyepiece(field number= 22mm) 0.10mm/Div | ● | |
Nosepiece | Quadruple (the center of nosepiece is adjustable ) | ● |
Quintuple(Backward ball bearing inner locating) | ○ | |
Objective | Strain-free plan achromatic objective | ● |
PL 4X/0.10 WD=19.8 mm | ● | |
PL10X/0.25 WD=5.0 mm | ● | |
PL 40X/0.65(S) WD=0.66 mm | ● | |
PL 60X/0.80(S) WD=0.45 mm | ● | |
PL 20X/0.40 WD=8.8mm | ○ | |
PL 60X/0.80 WD=0.46mm | ○ | |
Stage | Rotatable stage, diameter ¦µ150mm, 360° graduated (in 1° increments), minimum vernier division is 6' , center adjustable and with tightener. | ● |
Moving range: 30mmX25mm | ○ | |
Focus system | Coaxial coarse/fine focus with tension adjustable and up stop device, minimum division of fine focusing: 2μm. | ● |
Illumination | 6V30W halogen, brightness enable control | ● |
Rotatable 360°, have 0,90,180,270 scale¡£ | ● | |
Abbe condenser N.A. is 1.25 and add iris diaphragm | ● | |
Intermediate attachment | Integrated analyzer can be switched to normal or polarizing observe freely, enable 0~90° rotated and minimum vernier division is 12'. | ● |
Puller type bertrand lens and center adjustable. | ● | |
¦Ë, ¦Ë/4 and quarts wedge compensator. | ● | |
Compensator | ¦Ë, ¦Ë/4 and quarts wedge compensator. | ● |
C-Mount | 0.4X | ○ |
0.5X | ○ | |
1X | ○ | |
0.5X with dividing 0.1mm/Div | ○ |
Note: "●"In Table Is Standard outfits, "○" Is Optional Accessories.
1